Digital Mass Flow Sensor


  • Maximum applied voltage: 28V,  Maximum load current: 80mA, Internal voltage drop: less than 1V
  • D-analog output: 4~20mA Load impedance: 50~600Ω

 


Series KLFMA
TypeKLFMA 0125KLFMA 01100KLFMA 01200KLFMA 02500KLFMA 021000KLFMA 022000
FluidMediumDry air, N2, CO2, Ar, VacuumDry air, N2
FlowFlow Range (L/min)Air,N20.2~251~1002~2005~50010~100020~2000
CO20.2~12.51~502~100---
Setting Flow RangeInstantaneous Flow0.1 L/min1 L/min1 L/min
Cumulative Flow1 L10 L
Accumulated Pulse Output (L/pulse)0.111101010
PressurePressure Range-0.1~0.75 MPa0~0.8 MPa
Max. Pressure1.0 MPa
ElectricalSupply PowerDC12~24V±10%
Current Consumption35mA 以下55mA 以下
AccuracyDisplay Accuracy±3% F.S. ±1 digit
Analog Output Accuracy±3% F.S.
Repeat Accuracy±1% F.S. ±1 digit (±2% F.S. ±1 digit when digital filter 0.05s is selected)
Temperature±5% F.S. ±1 digit (0~50C: 25℃ reference)
Switch OutputOutput FormNPN open collector
Output ModeHysteresis mode/upper and lower limit comparison
mode/accumulated pulse output mode
Error output mode/switch output OFF mode
On/OffNPN/PNP open collector
Max. Load Current100mA
Max. SupplyDC30V
Internal Voltage DropNPN: 1V or less (load current 80mA)
Response Time50ms or less
Short Circuit ProtectionYes
Analog OutputOutput FormCurrent output: 4~20mA
ImpedanceVoltage OutputOutput impedance: about 1kΩ
Current OutputMaximum load impedance: 600Ω when power supply voltage is 24V, 300Ω when power supply voltage is 12V
Response Time50ms±40%